Changzhou DLX Alloy Co., Ltd.

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Thermocouple Extension Wire /

2x0.5mm 2x0.6mm 2x0.8mm Type E Thermocouple Extension Wire Metal Shield Fiberglass / PFA Insulated

Contact Now
Changzhou DLX Alloy Co., Ltd.
Visit Website
City:changzhou
Province/State:jiangsu
Country/Region:china
Contact Person:MrsJane
Contact Now

2x0.5mm 2x0.6mm 2x0.8mm Type E Thermocouple Extension Wire Metal Shield Fiberglass / PFA Insulated

Ask Latest Price
Video Channel
Brand Name :DLX
Model Number :Type E Thermocouple extension wire
Certification :CE,ROHS
Place of Origin :China
MOQ :5
Payment Terms :L/C, T/T, Western Union, MoneyGram
Supply Ability :300 tons per month
Delivery Time :5-21 days
Packaging Details :Spool package with Carton box, Coil package with polybag
Product name :Thermocouple E extension wire
Certificate :ISO9001
Temperature range :-200~900°C
EMF tolerance :+/- 2.2C or +/- .75%
Grade :Extension Grade Type K
Positive :Ni-cr
Negative :Cu-Ni
Special Limits of Error :+/- 1.1C or 0.4%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

2x0.5mm 2x0.6mm 2x0.8mm Type E Thermocouple Extension Wire Metal Shield Fiberglass/PFA Insulated Thermocouple Wire

  • Thermocouple Extension Wire

E-type thermocouple compensation wire is a high-performance connecting cable designed for E-type thermocouples. It is mainly used to extend the measurement loop of the thermocouple and compensate for the error caused by the change of the cold end temperature. It has excellent thermoelectric properties, high temperature resistance, corrosion resistance and good insulation. It usually uses a fluoroplastic insulation layer to ensure the stability and accuracy of signal transmission. It is widely used in industrial fields such as petroleum, chemical, metallurgy and electric power industries, and can effectively improve the accuracy and reliability of the temperature measurement system. When using it, pay attention to model matching, correct connection and avoid environmental interference to ensure the accuracy of the measurement.

Nickel-chromium-copper-nickel thermocouple (E-type thermocouple), also known as nickel-chromium-constantan thermocouple, is also a cheap metal thermocouple. Its positive electrode (EP) is nickel-chromium 10 alloy, with the same chemical composition as KP, and its negative electrode (EN) is copper-nickel alloy, with a nominal chemical composition of 55% copper, 45% nickel, and a small amount of cobalt, manganese, iron, etc. The operating temperature of this thermocouple is -200~900°C.


  • Thermocouple Wire
Code Wires component of the thermocouple
+Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)

  • ​Standards
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

Detailed Parameter of thermocouple wire

Working Temperature Range

Diameter/mm Long time Working temperature /ºC Short period Working temperature /ºC
0.3 700 800
0.5 800 900
0.8,1.0 900 1000
1.2,1.6 1000 1100
2.0,2.5 1100 1200
3.2 1200 1300

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200


  • Features
  1. High sensitivity: E-type thermocouples have high thermoelectric potential output, so their compensation wires can provide more accurate measurements.
  2. High temperature and corrosion resistance: The compensation wires are usually made of high temperature and corrosion resistant insulation materials, suitable for complex industrial environments.
  3. Strong anti-interference ability: Some compensation wires are shielded, which can effectively reduce electromagnetic interference.
  4. Usage temperature range: generally -25℃ to 200℃, suitable for a variety of environments.
  • Precautions for use
  1. Model matching: E-type thermocouples must use E-type compensation wires and cannot be mixed with other types.
  2. Correct polarity connection: The positive and negative poles of the compensation wire must be correctly connected to the positive and negative poles of the thermocouple and the measuring instrument.
  3. Environmental adaptability: Select the appropriate insulation sheath material according to the use environment, such as polytetrafluoroethylene for high temperature environments.
  4. Regular inspection and maintenance: The compensation wire may age after long-term use, and regular inspection is required to ensure measurement accuracy.

2x0.5mm 2x0.6mm 2x0.8mm Type E Thermocouple Extension Wire Metal Shield Fiberglass / PFA Insulated2x0.5mm 2x0.6mm 2x0.8mm Type E Thermocouple Extension Wire Metal Shield Fiberglass / PFA Insulated